Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Appl Gerontol ; 42(7): 1445-1455, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36919309

RESUMO

Cognitive vulnerability, that is, clinically significant symptoms of dementia, depression, or delirium, puts older adults at high risk for physical inactivity and falls. Programs addressing activity and falls are needed. The purpose was to determine feasibility of an in-home, modified, Otago Exercise Program (OEP) for those with cognitive vulnerability, based on acceptability (retention and adherence), safety (pain intensity and falls), and potential positive effects (change in short physical performance battery (SPPB)). This secondary analysis of a randomized controlled trial included 80 participants who received the OEP; 64 completed it, 48% had depression, 22% had dementia, and 30% had a combination dementia/depression/delirium. Adherence to home exercise was low to moderate; pain was stable over 16 weeks; 31% of participants reported falls unrelated to OEP. SPPB increased from 6.95 to 7.74 (p < .01); age by time and diagnosis by time interactions were not significant. The modified OEP shows promising feasibility for older adults with cognitive vulnerability.


Assuntos
Delírio , Demência , Humanos , Idoso , Terapia por Exercício , Estudos de Viabilidade , Equilíbrio Postural , Demência/terapia , Cognição
2.
Anal Chem ; 94(30): 10865-10873, 2022 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-35853140

RESUMO

Immunological detection of small molecules in a point-of-care (POC) format is of great significance yet remains challenging for accurate visual discrimination and quantitative analysis. Here, we report a novel hue recognition competitive fluorescent lateral flow immunoassay (HCLFIA) strip that allows both visual and quantitative detection of aflatoxin M1 (AFM1). The HCLFIA strip works on the basis of the ratiometric change of emission, arising from the overlap of fluorescence signals of two nanocomposites tagged with probe antibodies and coated antigens. A visually discernible orange-red-to-green fluorescence color change allows the naked eye semiquantitative readout of AFM1 around the threshold concentration (0.05 ng mL-1), yielding a visible detection limit of 0.02 ng mL-1. Moreover, using a custom smartphone-based device and color chart analysis, ultrasensitive quantitative detection of AFM1 can be achieved with a low limit of detection at 0.0012 ng mL-1, which is considerably better than those of the previously reported colorimetric and fluorescent strips. The accuracy performed in spiked milk samples ranged from 97.91 to 113.12% with a coefficient of variation below 7.8%, showing good consistency with the results from isotope dilution liquid chromatography-tandem mass spectrometry. Thanks to the unique hue recognition scheme, the HCLFIA strip holds great potential for POC detection of small molecules.


Assuntos
Aflatoxina M1 , Leite , Aflatoxina M1/análise , Animais , Contaminação de Alimentos/análise , Imunoensaio/métodos , Espectrometria de Massas , Leite/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...